FAQs | Questions & Answers
GH2+ CUSTODY TRANSFER METERING SYSTEM FOR GASEOUS HYDROGEN
To save you e-mails or phone calls, we have compiled the most frequently asked questions and answers about the TrigasDM GH2+ measuring system for you.
The devices must be tested every two years at the end of the calendar year.
You can have the device tested at any gas laboratory accredited to ISO 17025 (e.g. Trigas FI GmbH).
Use in tankers for hydrogen (trailers) such as MEGCs (Multi Element Gas Containers) and tube trailers (power supply through chassis). Currently not suitable for trailer exchange stations, but there will be a solution for this.
Yes, a type examination certificate from the PTB is available. Responsibility for compliance with the MessEV is transferred to the operator after the conformity assessment.
Currently in DE and AT. The approval process is underway in other countries such as FRA, BEL, NED and CH.
The conformity assessment is a test for compliance with legal regulations that is necessary for placing a measuring device on the market for custody transfer. Conformity assessment also plays an important role in ensuring quality, safety and environmental compatibility.
It is the responsibility of the manufacturer.
Calibration is a recurring metrological test after a legally defined calibration cycle has expired. It is important to note that calibration must be carried out in accordance with legal requirements and that the use of non-calibrated or non-compliant measuring devices can have legal consequences in many cases.
The responsibility here lies with the operator.
The pressure range of the systems goes up to 1048 bar and is designed specifically for the application.
We offer many different services, for example after-sales support, training for service providers and customers, flexible solutions according to customer requirements.
Extended measuring range, direct mass measurement without the influence of pressure and temperature, linear output signal, no moving parts.
There are both stationary and mobile measuring systems
Lead time 5 working days, see logistics concept.
Installation, dismantling and maintenance can be carried out by our authorized and trained service partners (Kläser, Frank Fahrzeugbau, Lindenau Fulltankserivce, TrigasFi GmbH, VCT-Vogel).
Nehmen Sie Kontakt mit uns auf. Wir freuen uns auf Sie.